CrosStar’s ATU Advance Telemetry Unit provides advance telemetry and control for water and wastewater systems. The design of the ATU incorporates state of the art technologies in manufacturing, communications, controls, and serviceability. With its modular design, the ATU can be cost effective as a simple Water Tank remote or scaled up to handle the complex control of sequenced filtration processes.
An ATU Advance Telemetry Unit is made up of individual modules that plug together to form the desired control and telemetry unit. A complete assembly is comprised of several types of modules according to the needs of a particular station. Module types available are several CPU processor units, digital inputs, digital outputs, RS232 or RS485 serial channels, analog input/outputs, several power supplies, modems, network, and radio modules. All modules used in the ATU have automatic addressing thus simplifying setup when adding or changing types. No switches, jumpers or pots need to be adjusted on any module in order to make it function. This includes analog modules, which are scaled automatically to the previous values upon replacement. Up to 18 input/output modules and up to 4 modem/serial/radio/network modules can be assembled as one ATU.
Features
- Easy Chassis Panel Mounting.
- The CPU, Communication, and Input/Output Modules All Mount Individually Into The Rack Assembly.
- Quick-Connection Terminals on Modules Make Module Replacement and Testing a Snap.
- Simple Setup Using CrosStar's Windows Based ATU Advocate Software Via Standard RS-232 Port.
- Integral Power Supply with Battery Backup and Charger Circuitry Provides Complete DC Power for most Remote Sites, Including Telemetry Radios.
- Scalable Functionality from Simple Tank Transmitter to Complex Filter Control.
Description
The ATU Advance Telemetry Unit has an integral power supply with built-in battery charger and bump-less power fail battery switch over circuitry. The power supply uses standard 115 volts AC, and provide the requirements of the ATU, plus supply both +12 Vdc and +24 Vdc power for other low voltage cabinet mounted equipment, including the telemetry radio transceiver. The battery charger is designed to provide rapid recharging and maintenance float charging of gel-cell type batteries. Power failure, low battery voltage, and failing battery conditions are monitored by the Power Supply and these alarm signals are passed to the CPU. The Power Supply detects a failing battery by measuring the battery discharge decay rate on a routine basis.
Several versions of the CPU module are available to match the control needs of the system. All the CPU modules have integrated real-time clocks and store the communication and control configuration in Flash EPROM. Over 30 different control tag types are available allowing very complex control schemes to be created easily and quickly using CrosStar's Window's based ATU Advocate Software.
Digital Input modules are available in several styles including low voltage self-powered dry contact style and 24/115 Volt AC coil style. All digital input modules have individual status indicating lights, and are configurable as momentary (latched) input. Also most of the Digital Input modules have input points which can be configurable as high-speed pulse inputs to interface with pulse output style instruments such as flow meters, rain gauges and wind meters.
Digital Output modules are available as either low voltage transistor style, or 12-115 volt 10 amp isolated relay dry contact style. Output commands to the Digital Outputs use a "select, check, operate" sequence to verify the integrity of each output point constantly. Also each Digital Output can be configured with the Alarm Flash option which operates with the internal Alarm Horn and Silence/ Acknowledge signals to greatly simplify alarm annunciations.
Analog Inputs on the ATU are available for both 0-5 V and 4-20mA current loop. Each analog input connection is supplied with battery backed up +24 VDC allowing loop-powered transducers to be easily connected. Each analog is converted and scaled to an IEEE-754 32-bit floating point number.
An ATU can have up to four communication channels providing interface to a host of intelligent equipment and protocols. Available communication modules include RS-232, RS-485, Lease-Line/Radio and POTS Dialup Modems, Spread Spectrum Radios, 100/10Base-T and WiFi Networking, and Cellular Radio. Protocols include Modicon's Modbus, Allen-Bradly DF-1, Aquatrol W1500 Telemetry, HDLC, and CrosStar's Smart™ protocol.
The standard communication system used by the ATU is CrosStar's Smart™ Telemetry System employing Auto Repeat Message Routing and Message Packing to make efficient use of the radio channel, which lowers power consumption and decreases the scan time of the system. The Smart™ Telemetry System, when necessary, automatically determines the best repeat path to every telemetry remote unit, and constantly updates this information. Every ATU has the ability to repeat messages as needed using a message packing system with the ability to store messages from several others remote sites, then send them all to the telemetry central in one transmission.
Specification Overview
(See Individual Module Data Sheets For Complete Specifications.)
|
General
|
|
|
Size:
|
Min: 5 L x 5 W x 6 H Inches.
|
|
|
Max: 24 L x 5 W x 6 H Inches.
|
|
Weight:
|
1 to 10 Pounds Depending On Configuration.
|
|
Temperature:
|
0 to +70 C.
|
|
Humidity:
|
0 to 95%.
|
|
Mounting:
|
Chassis Panel.
|
|
|
|
|
Power Supply:
|
ATU-APS100 Power Supply
|
|
Input Voltage:
|
120 VAC @ 0.5 Amp.
|
|
Output Voltage:
|
12 VDC @ 6 Amp Peak.
|
|
Battery Charger:
|
Design /w Rapid Recharging and Maintenance Float.
|
|
Internal Alarms:
|
Power Fail, Low Battery Voltage, Bad Battery.
|
|
Front Panel:
|
Four Status LEDs:
|
|
|
Bad Battery, Red
|
|
|
Test Battery, Yellow
|
|
|
Power Fail, Red
|
|
|
Low Battery, Yellow
|
|
|
|
|
Power Supply:
|
ATU-APS200 Power Supply With 3 Communication Slots
|
|
|
Power Supply Plus Three (3) Communication Module Slots.
|
|
Input Voltage:
|
120 VAC @ 0.5 Amp.
|
|
Output Voltage:
|
12 VDC @ 6 Amp Peak.
|
|
Battery Charger:
|
Design /w Rapid Recharging and Maintenance Float.
|
|
Internal Alarms:
|
Power Fail, Low Battery Voltage, Bad Battery.
|
|
Front Panel:
|
Four Status LEDs:
|
|
|
Bad Battery, Red
|
|
|
Test Battery, Yellow
|
|
|
Power Fail, Red
|
|
|
Low Battery, Yellow
|
|
|
|
|
Processor Module:
|
ATU-CPU10 Processor Module
|
|
Processor Type:
|
High Speed 8 Bit Microprocessor With 16 Bit Extensions.
|
|
Flash Memory:
|
256K Byte
|
|
RAM Memory:
|
128K Byte
|
|
Serial Ports:
|
Two: One RS-232
|
|
|
One RS-485
|
|
Front Panel:
|
Four Status LEDs:
|
|
|
Power On
|
|
|
Control Program Running
|
|
|
System Fault
|
|
|
Serial TX and RX
|
|
|
Two Switches:
|
|
|
Program Run-Off-Program.
|
|
|
CPU Reset.
|
|
Language:
|
Functional Tag Based Control Language.
|
|
Misc. Features:
|
Non-Volatile Real-Time Clock.
|
|
|
Cabinet Temperature Sensor.
|
|
|
|
|
Input/Output Module:
|
ATU-M842 Combo I/O Module
|
|
Digital Inputs:
|
8 Self-Powered Dry Contact Style.
|
|
Digital Outputs:
|
4 Low Voltage Transistor Style.
|
|
|
0-30 VDC, 100 mA Max.
|
|
Analog Inputs:
|
Two 1-5V or 4-20mA
|
|
|
With Battery Backed +24 VDC Transducer Supply.
|
|
Pulse Input:
|
On Digital Input 1, 0-500KHz
|
|
Front Panel:
|
Ten Status LEDs:
|
|
|
Module Selected
|
|
|
Analog Fault
|
|
|
One LED Per Digital Input
|
|
|
|
|
Digital Output Module:
|
ATU-DOR5 5 Circuit Relay Output Module
|
|
Digital Outputs:
|
Five Isolated Relays.
|
|
|
0-120 V AC/DC. 10 Amps Max.
|
|
|
1/3 HP Rated.
|
|
Functions:
|
Alarm Light Operation.
|
|
|
Alarm Horn Operation
|
|
|
Select/Check/Operate
|
|
Front Panel:
|
Four Status LEDs:
|
|
|
Module Selected
|
|
|
One LED Per Digital Output
|
|
|
|
|
Digital Input Module:
|
ATU-DIAC 12 Circuit AC Digital Input Module
|
|
Digital Inputs:
|
12 110 VAC Input Coil Style.
|
|
|
70-130 Volt AC, 20 mA Max.
|
|
Front Panel:
|
13 Status LEDs:
|
|
|
Module Selected
|
|
|
One LED Per Digital Input
|
|
|
|
|
Digital Input Module:
|
ATU-DI12 12 Circuit Low Voltage Input Module
|
|
Digital Inputs:
|
12 Low Voltage Input Style.
|
|
|
0-30 Volt AC/DC, 20 mA Max.
|
|
Pulse Input:
|
On Digital Input 1, 0-500KHz
|
|
Front Panel:
|
13 Status LEDs:
|
|
|
Module Selected
|
|
|
One LED Per Digital Input
|
|
|
|
Documents
- CrosStar ATU™ Advance Telemetry Unit General Overview Data Sheet (10-1018B)
PDF Version (307K)
Last Updated: 2/15/05
- CrosStar ATU Advocate Configuration Software Data Sheet (10-1017A)
PDF Version (1,297K)
Last Updated: 2/21/05
- CrosStar ATU™ Advance Telemetry Unit Modules (70-1000D)
PDF Version (279K)
Last Updated: 5/16/06
- CrosStar ATU-CPU10 Processor Module Data Sheet (10-1019A)
PDF Version (1,501K)
Last Updated: 2/25/05
- CrosStar ATU-CPU20 Processor Module Data Sheet (10-1033A)
PDF Version (1,501K)
Last Updated: 2/25/05
- CrosStar ATU-RS232 RS-232 Communication Module Data Sheet (10-1024A)
PDF Version (2,276K)
Last Updated: 2/26/05
- CrosStar ATU-RS485 Short Haul Modem Communication Module Data Sheet (10-1025A)
PDF Version (2,105K)
Last Updated: 2/26/05
- CrosStar ATU-MOD202 1200 Baud Bell 202 Modem Module Data Sheet (10-1026A)
PDF Version (2,372K)
Last Updated: 2/27/05
- CrosStar ATU-MOD202-A 1200 Baud Bell 202 Modem Module Data Sheet (10-1035A)
PDF Version (2,405K)
Last Updated: 5/25/05
- CrosStar ATU-MODHDLC Tone Modem With HDLC Module Data Sheet (10-1036B)
PDF Version (939K)
Last Updated: 9/22/06
- CrosStar ATU-MODNIC 100/10Base-T Ethernet Network Module Data Sheet (10-1029A)
PDF Version (737K)
Last Updated: 9/22/06
- CrosStar ATU-RAD900 900 MHz Spread Spectrum Radio Communication Module Data Sheet (10-1028A)
PDF Version (720K)
Last Updated: 5/17/06
- CrosStar ATU-M842 Combination Input/Output Module Data Sheet (10-1020A)
PDF Version (2,689K)
Last Updated: 2/28/05
- CrosStar ATU-DOR5 5 Relay Output Module Data Sheet (10-1021A)
PDF Version (1,798K)
Last Updated: 2/27/05
- CrosStar ATU-DIAC 12 Circuit AC Digital Input Module Data Sheet (10-1022A)
PDF Version (2,381K)
Last Updated: 5/25/05
- CrosStar ATU-DI12 12 Circuit Low Voltage Digital Contact Input Module Data Sheet (10-1034A)
PDF Version (2,383K)
Last Updated: 5/25/05
- CrosStar ATU-APS100 Standard Power Supply Module Data Sheet (10-1030A)
PDF Version (217K)
Last Updated: 3/08/05